TLSC1
South African style temperature assembly

TLSC1
South African style temperature assembly ©Endress+Hauser

Comprehensive and common temperature measurement technology for almost all branches of industry

The thermometer is mainly used in the chemical industry but also finds its use in other branches. The device with head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability compared to directly wired sensors. To be installed into a thermowell or directly into the process by means of an adjustable or fixed fitting. It can also be used in all applications where small immersion lengths are needed.

  • Avantages

    • Various types of thermocouples: Type J (Fe-CuNi), type K (NiCr-Ni), type N (NiCrSi-NiSi) or type T (Cu-CuNi)

    • Sheath material ANSI 316SS or 310SS, INCONEL 600

    • Customized immersion length

    • Electrical connection by means of a ceramic terminal block or head...

  • Domaine d'application

    Thermocouple sensor for industrial applications. It comprises of various diameter fixed inserts with either a transmitter mounting plate or a ceramic terminal block. The hot junction can be either "grounded" or "ungrounded" from the sheath. The terminal...

Caractéristiques et spécifications

Retour

Details

  • Principe de mesure

    Thermocouple

  • Caractéristiques / Applications

    Style S.A. Style

    Gamme d'application universelle

    Peut être utilisé avec ou sans protecteur

  • Tête de raccordement

    Grand choix de têtes possible

    Matériaux de construction possibles : PVC, aluminium, inox 316

    Options de sorties mixtes possibles

  • Protecteur / tube de protection

    A utiliser avec ou sans protecteur (peut être commandé séparément)

  • Insert / Sonde

    à isolation minérale (MI), flexible

  • Longueur dʹimmersion sur demande

    jusqu'à 90.000 mm (3.543,31'')

  • Matériau tube de protection/protecteur

    1.4401 (316)

    1.4841 (310)

    Alloy 600 (2.4816)

  • Revêtement en option

    Non défini

  • Raccord process

    Filetage fixe :
    NPT 1/4"

    NPT 1/2"

    G1/2"

    Raccord ajustable :

    NPT 1/8"

    NPT 1/4"

    NPT 3/8"

    NPT 1/2"

    G1/2"

  • Forme de lʹextrémité

    Droite

  • Gamme de temperature de service

    Type J :

    -210 ...760 °C

    (-346 ...1.400 °F)

    Type K :

    -270 ...1.100 °C

    (-454 ...2.012 °F)

    Type N :

    -270 ...1.100 °C

    (-454 ...2.012 °F)

    Type T :

    -270 ...400 °C

    (-454 ...725 °F)

  • Pression process max. (statique)

    à 20 °C : 10 bar (150 psi) sans protecteur

  • Précision

    Classe 1 selon IEC 60584

  • Temps de réponse

    Selon la configuration

  • Intégration transmetteur en tête

    oui (4 ... 20 mA ; HART ; PROFIBUS PA ; FOUNDATION FIELDBUS)

  • Certification

    Traçabilité certificat matière 3.1 EN10204

Documents / Manuels / Logiciels

Accessoires / pièces de rechange

Nr
Order code
Specification
    • Order code 71044061

      Kit de fixation cplt TMT85/84 EU (europe

      2x vis, 2x ressorts, 2x rondelles, 1x joint de connecteur CDI

    • Order code TMT181-

      iTEMP TMT181, transmetteur de temp. PCP

      Transm. de temp. programmable par PC Entrée: Pt100, TC, Ohm ou mV Sortie 2 fils 4-20mA, isolation galv. Mode défaut selon NAMUR NE 43 Montage: tête forme B, DIN EN50446 Listé UL.

    • Order code TMT84-

      iTEMP TMT84, transmetteur PA

      Transmetteur de température à 2 entrées. Diagnostic avancé: monitoring capteur. Profibus PA Profile 3.02. Isolation galvanique 2kV. Entrée: Pt100, TC, Ohm ou mV. Consommation de courant: 11 mA. Montage: tête forme B, DIN EN50446. Réglage usine: CH1: Pt100, 3-fils, oC CH2: inactif. Différents choix de configurations en option.

    • Order code TMT85-

      iTEMP TMT85, transmetteur de temp. FF

      Transmetteur de température à 2 entrées Diagnostic avancé: monitoring capteur Protocole FOUNDATION Fieldbus Isolation galvanique 2kV Entrée: Pt100, TC, Ohm ou mV Consommation de courant: 11 mA. Montage: tête forme B, DIN EN50446 Réglage usine: CH1: Pt100, 3-fils, oC CH2: inactif Différents choix de configurations en option

  • B
    • Nr B Order code TID10-

      Afficheur TID10

      Pour montage en tête de sonde, embrochable sur transmetteur. Compatible avec TMT82, TMT84 et TMT85. Affichage de la valeur mesurée . 12 DIP-switches sur face inférieure. Réglages: FF: Simulation, Ecriture verrouillée

    • Order code TMT182-

      iTEMP TMT182, transm.de température HART

      Transm. de temp. avec protocole HART Entrée: RTD, TC, Ohm, mV. Sortie 2 fils 4-20mA, isolat.galvanisée Mode défaut selon NAMUR NE 43 Montage: tête forme B, DIN EN50446 Listé UL.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      Transmetteur de température 2 entrées Séparation galvanique 2kV (entrée/sortie) Entrée: Pt100, TC, Ohm ou mV. ::Très fiable en raison de la détection de la dérive et du capteur de secours. ::En option: Donc, pour les applications critiques de sécurité par le moyen de SIL 2/3 selon. IEC61508.

    • Order code FXA195-

      Commubox FXA195

      Modem HART/USB pour la configuration et la maintenance de l'instrumentation HART via un logiciel sur PC :: Le module s'utilise hors zone, mais peut se connecter sur une boucle SI :: Sil2, IEC61508

    • Order code READWIN-

      Readwin 2000 Logiciel config.+ visualis.

    • Order code TXU10-

      Kit de configuration TXU10-

      Pour transmetteurs programmables par PC Logiciel de configuration + câble d'interface PC USB.

    • Order code 51001112

      Pièces de rech. pour TMT181/187/188/182

      (4 vis, 6 ressorts, 10 rondelles élast.)